Toggle Load Cell
Friday, 01 July 2005
The DYS range of Tension Toggle Load Cells have been designed for general use and are particularly suitable for permanent installations where wire loads are being measured.

They are built to exacting standards and are suitable for use in exposed situations and can be supplied to withstand immersion in sea water.

This range of load cells are Proof Loaded to 150% of the normal rated load.



Image ©  carlo Borlenghi





Bridge Resistance350 Ohms
Excitation5 -10V DC, Max 15V DC
Output (Nominal)1.0mV/V at Rated Load
Insulation Resistance>500 MOhm @ 100V DC
Operating Temperature-20°C to +70°C
Compensated Temp. Range-10°C to +50°C
Zero Temp Coefficient0.01% of Rated Load /°C
Span Temp Coefficient0.01% of Rated Load /°C
Non-linearity<+/- 0.2% of Rated Load
Non-repeatability+/- 0.04% of Rated Load
Proof Load150% of Rated Load
Ultimate Breaking Load>300% of Rated Load
ProtectionIP67
Cable4-core Screened
ConnectionsRed +ve supply, Blue -ve supply
Yellow -ve signal, Green +ve signal


The full range is available in EYE to EYE geometry; all other details remain the same.